IDEC Corporation announces built-in support for the BACnet/IP building automation protocol by its family of MicroSmart FC6A Plus PLCs. BACnet stands for Building Automation and Control Networking Protocol, and it is the world’s leading protocol for networking HVAC, lighting, security and other systems commonly found in commercial and industrial buildings.

IDEC Corporation announces built-in support for the BACnet/IP building automation protocol by its family of MicroSmart FC6A Plus PLCs. BACnet stands for Building Automation and Control Networking Protocol, and it is the world’s leading protocol for networking HVAC, lighting, security and other systems commonly found in commercial and industrial buildings. This open protocol has been standardized under the ANSI/ASHRAE 135-2012 specification for interoperability among systems built by different manufacturers.

Built-in support for the latest version of BACnet, BACnet/IP and its B-ASC profile allows equipment and systems using IDEC’s MicroSmart FC6A Plus family of PLCs to act as a BACnet Server and thus easily connect via the PLC’s Ethernet Port 1 to other building automation BACnet Client controllers and systems for data sharing, trending, scheduling, alarm and event management, device and network management, and other functions. Supported PLC object types analog input, analog output, analog value, binary input, binary output, binary value and device. Up to 256 objects can be simultaneously supported, with up to 64 bytes of characters for each.

Support is provided for Subscribed COV (change of value), Unsubscribed COV and Foreign Device functions. With the Subscribed COV function, the BACnet Client sends a subscribe request, and the BACnet Server, such as an IDEC MicroSmart FC6A Plus PLC, sends “Present Value” and “Status Flags” when these parameters change.

The Unsubscribed (or Unsolicited) COV function is similar, but in this case the BACnet Client does not need to send a subscribe request to the BACnet Server because it sends the designated data to the Client whenever the data it changes.

The Foreign Device function permits an external BACnet device to be linked to a BACnet/IP Broadcast Management Device (BBMD). If the device is registered to the BBMD, the device can communicate to other devices linked to the BBMD

Configuration for BACnet communications via IDEC’s MicroSmart FC6A Plus family of PLCs is done with drop-down menus by simply clicking on the “BACnet/IP Settings” tab and following the on-screen instructions. Two main settings are required: Device ID and Register Objects.

Added objects are listed on a tree, and the properties for each object are configured by entering data into a grid. Typical object properties or settings include property name, device control, initial value, device assignment and others.

MicroSmart FC6A Plus PLCs already exceed the competition with premium features including 2060 digital I/O, 511 analog I/O, Bluetooth communication, FTP Client/Server protocol, SD memory for data logging, dual Ethernet ports and the WindEDIT Lite App for iOS and Android. Now, with the introduction of support for the BACnet/IP protocol, users can expect even more capabilities, all with no extra hardware required or added cost. With just a simple firmware upgrade in the latest version of WindLDR programming software, configuring BACnet/IP is simple and intuitive.

As with all of its other products, IDEC offers free tech support with no service or support contract required. For complete specifications or additional information, please contact IDEC Corporation at 800-262-IDEC (4332), or click here.

Sponsored Recommendations

Rock Quarry Implements Ignition to Improve Visibility, Safety & Decision-Making

George Reed, with the help of Factory Technologies, was looking to further automate the processes at its quarries and make Ignition an organization-wide standard.

Water Infrastructure Company Replaces Point-To-Point VPN With MQTT

Goodnight Midstream chose Ignition because it could fulfill several requirements: data mining and business intelligence work on the system backend; powerful Linux-based edge deployments...

The Purdue Model And Ignition

In the automation world, the Purdue Model (also known as the Purdue reference model, Purdue network model, ISA 95, or the Automation Pyramid) is a well-known architectural framework...

Creating A Digital Transformation Roadmap Using A Unified Namespace

Digital Transformation has become one of the most popular buzzwords in the automation industry, often used to describe any digital improvements to industrial technology. But what...