Belden Inc: Profinet I/O Modules

Sept. 13, 2012
Lumberg LioN-M I/O PROFINET modules allow easy cabling, individual I/O configuration and precise diagnostics.

Designed for machines and systems with high signal density and stringent real-time requirements, the new modules support both the real time (RT) and isochronous real time (IRT) standards. In the 0980 ESL 701 (16 DI) module, channels are used as inputs, and in the universal version 0980 ESL 700 (16 DIO Universal) they are used as either inputs or outputs in any combination up to a total of 16 points and has a rated output current of up to 1.6A, with a maximum total current capacity of 9A. Easy diagnostics enable precise fault location for each individual port. Both modules facilitate line topologies and can also be used for existing communications structures such as cable ducts and energy chains without making any changes to their physical layout. Both network ports are equipped with four-pole M12 connectors with D coding. The eight I/O ports, each of which can be assigned to two digital I/O signals, have five-pole M12 connectors with A coding. These PROFINET IO modules support DCP and LLDP. DCP protocol is used to assign the unique PROFINET device name to the module. By this device name the module is clearly identified in the PROFINET network.